IMJ00503 V3E.DOC Page 22 of 40 19.02.2009
10 bool E54: hardware error (PLL)
11 bool E55: hardware error
12 bool E61: selected parameter is illegal; invalid command was
triggered
13 bool E62:
1. hardware error
2. false value for interface communications (parity error
SIO)
14 bool E63: overflow SIO
15 bool E64 . framing error SIO
20..21 word warnings . unused (=0)
22..23 word warnings . unused (=0)
24..25 word profile version (z.B. 1.1 = 0110 hex)
26..27 word software version (z.b. 1.11 = 0111 hex)
28..31
unsigned
32
operating time (of laser), in units of 0.1 hour
32..35 signed 32 offset value (alsoe refer to output data)
36..39 signed 32 manufacture offset . unused (=0)
40..43
unsigned
32
unsigned 32 measuring units per revolution . unused
(=0)
44..47
unsigned
32
unsigned 32 measuring range . unused (=0)
48..57 10 byte 10 byte serial number
58..59 word word reserved for future use
60 signed byte laser temperature in °C
61 byte reserved unused
Since the LMC J 0050 3 is a linear encoder that measures absolute distances, the four
parameters “code sequence”, ”scaling function control“, ”Measuring units per revolution“ and
”Measuring range in measuring units“will be ignored.